Code 81- Exhaust Temp Sensor- input voltage high

Code 81- Exhaust Temp Sensor- input voltage high

Incorrect calibration installed for Application group.06N04C1706 - is for cold climate and not used in Australia due to the chance of engine overheating faults due to the fan on time at higher temperature.Should have either 06N04C0779 or 06N04C0781 (most recent).
    • Related Articles

    • Fault Codes,error code, error, alarm, CPC, MCM, ACM

      Fault Codes,error code, error, alarm, CPC, MCM, ACM
    • Terex OM934LA Adblue Tank Level & Temp sensor

      Generally for Ad-blue components e.g. doser valves/Ad-Blue injectors and other sensors, to interpret the parts you need the AGS-number which you then input into the EPC system as per the attached presentation.However the Ad-blue tank and sensor are ...
    • ADEC fault code 83 logic and troubleshooting.

      Attached is a logic and troubleshooting procedure for fault finding low common rail fuel pressure in ADEC controlled S4000 engines.
    • DEIF service code reset

      ResetCode for maintenance Alarm is"2002" The maintenance alarm you are seeing is one of twopossible standard 'maintenance' timers in the DEIF controller. It is normallyset for 365 days (alarm 1) or 500 hours running (alarm 2). It can beturned off if ...
    • ECS UNI fault code

      Fault code listing and diagnostic help MTU document E531 403 / 02E