This may come in handy when troubleshooting low power and/or no code situations.
Regarding recording parameter 1.1075.065 “Torque Limitation Code” the values are as follows:
1 DBR (only limited by DBR curve, i.e. no active limitation)
2 Sensor Defect
4 Stop
8 Charge Air Pressure
16 Protection (e.g. derate due to oil temp / coolant temp / exh temp / charge air temp, etc)
32 Plant (can be limitation request via PAU)
512 Minimum common rail fuel pressure not reached
32768 Sensor Defect of critical sensors.
For measuring points that have a torque limit, limitation of torque starts as soon as the Lim1 within ADEC is reached. An alarm is not generated until
(i) the limited torque drops below a certain value and
(ii) it has been below that value for a certain time
The value in (i) and the time in (ii) are ADEC parameters and the exact behaviour of the limitation can be worked out by looking at those parameters in DIASYS (usually 1-D parameters but as you would know some are 2-D limit curves).