DDDL customer calibration send

DDEC reprogramming sending customer claibration changes fault.

When sending DDDL Off-Highway customer calibration changes to the main frame (e.g. inputs or outputs) you can get the following fault message.
max_vsl_spd constraint failed. 
OnChangemax_vsl_spd: Failed- 2, out of range.

To resolve the issue you enable the vehicle speed sensor along with the inputs or out puts you may be changeing then send all changes.
Lastly you turn off the vehicle speed sensor.
complete 
    • Related Articles

    • Fault Codes,error code, error, alarm, CPC, MCM, ACM

      Fault Codes,error code, error, alarm, CPC, MCM, ACM
    • DDEC Calibration settings - Hitachi EH3500AC3

      Attached is example of standard original supplied DDEC calibration set up for EH3500AC-3 haul truck. Below is summary of original factory supply. MODEL: T1237K33 (12V4000C21) Tier 1 / EO APPL GROUP:   06N04C0781    DESCRIP:  APPL DDEC C&I ELEC DRV ...
    • 16v4000-01 DDEC Mining truck improved FCO calibrations

      Factory has performed extensive further work on DDEC typical mining cals for improved fuel cons / performance at published power / suitable gov gains etc. Factory now releasing new FCO ordered engines with these cals and we are also implementing from ...
    • DDEC Calibration settings - Hitachi EH5000AC3

      Attached is example of standard original supplied DDEC calibration set up for Hitachi EH5000AC-3 haul truck. Below is summary of original factory supply. MODEL: T1637K11  (16v4000C31)  APPL GROUP:   06N04C0781    DESCRIP:  APPL DDEC C&I ELEC DRV ...
    • DDEC Calibration setting - Hitachi EH4000AC3

      Attached is example of standard original supplied DDEC calibration set up for Hitachi EH4000AC-3 haul truck. Below is summary of original factory supply. MODEL: T1637K33  (16v4000C21) Tier 1 / EO APPL GROUP:   06N04C0781    DESCRIP:  APPL DDEC C&I ...