DiaSys connection to engines with EIM and BVNG
If you have to connect DiaSys to an engine with EIM and Blue Vision New Generation (BVNG) monitoring you need an additionalCAN adapter cable with the MTU part number X00E50205939 and the connection point for DiaSys is on the engine. Further information on required tools can be looked up in the "MTU DDC and Mercedes Electronics tooling Guide" on The Hub
Related Articles
MTU BVNG - Idle Speed Increase Button
Please find attached drawing of the optional “Increase Idle Speed” function. A 2 core cable will need to be run from the control station button to each LOP in the engine room on plug X34, pins 3 & 11. Also pins 4 & 12 will need to be looped out as ...
Twin Disc RCS
Attached details how to connect TD EC300, EC600 and ZF Cruise command to BVNG basic LOP 13
Resetting run time of ADEC injectors with Diasys
Diasys run time re-set process when replacing ADEC injectors
Diasys recording Evaluation Template
Templates can be made for repeated viewing of a set of parameters for issues that can arise across multiple engines. Example: Engines in a fleet.
Showing engine serial number in DiaSys graph
If you evaluate a DiaSys recording of multiple engines and you are unsure which value is from which engine serial number you can display the engine serial numbers in the graph.Do a right mouse click on the graph, select "Additional Info" and ...