DiaSys connection to engines with EIM and BVNG

DiaSys connection to engines with EIM and BVNG

If you have to connect DiaSys to an engine with EIM and Blue Vision New Generation (BVNG) monitoring you need an additionalCAN adapter cable with the MTU part number X00E50205939 and the connection point for DiaSys is on the engine. Further information on required tools can be looked up in the "MTU DDC and Mercedes Electronics tooling Guide" on The Hub
    • Related Articles

    • MTU BVNG - Idle Speed Increase Button

      Please find attached drawing of the optional “Increase Idle Speed” function.  A 2 core cable will need to be run from the control station button to each LOP in the engine room on plug X34, pins 3 & 11. Also pins 4 & 12 will need to be looped out as ...
    • Twin Disc RCS

      Attached details how to connect TD EC300, EC600 and ZF Cruise command to BVNG basic LOP 13
    • Resetting run time of ADEC injectors with Diasys

      Diasys run time re-set process when replacing ADEC injectors
    • Diasys recording Evaluation Template

      Templates can be made for repeated viewing of a set of parameters for issues that can arise across multiple engines. Example: Engines in a fleet.
    • Showing engine serial number in DiaSys graph