MTU Engines - Bacteria Contamination in Cooling System - Approved Flush

MTU Engines - Bacteria Contamination in Cooling System - Approved Flush

If a cooling system presents with bacteria contamination or light corrosion, the Kluthe Hakutex 111 product is a locally available MTU approved cleaning agent. 



As always, please refer to the latest Fluids and Lubrications Specifications manual for further information. 
    • Related Articles

    • MTU Specifications for Liquid Fuels - (Diesel)

      MTU specifications for liquid fuels (Diesel) can be found in the Fluids and Lubricants Specifications manual.  Section 5. Liquid Fuels has all of the required information needed when evaluating fuel type and quality for MTU engines.  Attached is a ...
    • Cooling System Preservation

      There is no alternative products that can be used which are not listed in the Preservation and de-preservation manual.  Houghton 9156 is an approved product and still suitable to use in a "unfilled" situation. All P133 products (Glysacorr and ...
    • Biodiesel literature for MTU engines

      The use of Biodiesel within MTU engines has certain limitations and considerations required and is a readily changing subject as experiences and situations change - to ensure the latest current discussions are utilised alwasy reference initially the ...
    • 12V2000M70 cooling system diagram

      See attached FAT for 12V2000M70 engine.Also find the cooling system schematics and drawings.
    • Preheater setpoints for MTU Onsite Energy Gensets

      If a customer wishes to lower the set point of the jacket heaters on MTU OE gensets, for example to lower the base standby load of the installation, then there will normally be a Limit alarm in the ECU that will trigger if the temperature falls too ...